[Jan 06, 2022] NS0-175 Exam Dumps - Network Appliance Practice Test Questions
New Real NS0-175 Exam Dumps Questions
NetApp NS0-175 Exam Topics:
| Section | Objectives |
|---|---|
| Networking | - Describe Cisco networking components used within FlexPod designs - Demonstrate knowledge of FlexPod networking configurations |
| Flexpod Design | - Describe FlexPod components based upon customer workloads - Describe how to size a solution based on customer requirements in accordance with FlexPod best practices - Describe the support options for FlexPod |
| Security | - Describe access control methods for FlexPod solutions - Describe the considerations in building a secure multitenancy design |
| Tools | - Describe resources for determining supported FlexPod components - Demonstrate knowledge of using tools for managing FlexPod - Demonstrate knowledge of troubleshooting methodologies for FlexPod solutions |
NEW QUESTION 25
Which one of the following access methods will maintain boot messages across reboots?
- A. RSH
- B. Console
- C. Telnet
- D. SSH
Answer: B
NEW QUESTION 26
Two of the below statements are untrue. Select them.
- A. The Messages log file cannot be pushed to a remote FTP server in compressed format.
- B. The Messages log file can be pushed to a remote FTP server at scheduled intervals
- C. The HTTP log file cannot be pushed to a remote HTTPS server at scheduled intervals.
- D. The HTTP log file can be pushed to a remote FTP server in compressed format
Answer: B,C
NEW QUESTION 27
You are designing your drive layout for a NetApp E-Series storage array. You want to minimize performance bottlenecks by spreading data, parity, and spare capacity across all available drives.
In this scenario, which feature would accomplish this task?
- A. FlexVols
- B. RAID-DP
- C. Dynamic Disk Pools
- D. Virtual Storage Tiering (VST)
Answer: C
NEW QUESTION 28
You received from a customer the requirements shown below.
25 servers
25GbE connectivity
NFS and iSCSI protocols
30 TB flash storage
50 TB hybrid storage
In this scenario, which FlexPod solution would satisfy the requirements?
- A. Cisco UCS 6454 Fabric Interconnect, Cisco B-Series servers, Cisco Nexus 9300 Series, NetApp AFF A400, and FAS2750
- B. Cisco UCS 6332 Fabric Interconnect, Cisco B-Series servers, Cisco Nexus 9300 Series, NetApp AFF A400, and FAS8300
- C. Cisco UCS 6324 Fabric Interconnect, Cisco B-Series servers, Cisco Nexus 9300 Series, NetApp AFF A400, and FAS2750
- D. Cisco UCS 6454 Fabric Interconnect, Cisco B-Series servers, Cisco Nexus 9300 Series, NetApp AFF A400, and FAS8300
Answer: B
NEW QUESTION 29
You are asked to configure your company's new Cisco MDS switch so that the engineering department's FC storage traffic is logically isolated from the marketing department's traffic.
In this scenario, what will accomplish this task?
- A. VXLAN
- B. VPN
- C. VSAN
- D. VLAN
Answer: C
NEW QUESTION 30
Which of the following TWO statements are FALSE?
- A. The Messages log file cannot be pushed to a remote FTP server in compressed format.
- B. The Messages log file can be pushed to a remote FTP server at scheduled intervals
- C. The HTTP log file cannot be pushed to a remote HTTPS server at scheduled intervals.
- D. The HTTP log file can be pushed to a remote FTP server in compressed format
Answer: B,C
NEW QUESTION 31
Exhibit:
Your customer wants to consolidate their multiple data center applications into a single FlexPod solution. The customer wants to maintain the current network protocols and storage tiers.
Referring to the exhibit, which set of FlexPod components satisfies the requirements?
- A. Cisco UCS 6332-16 Fabric Interconnect, Cisco B-Series servers, Cisco Nexus 9000 Series, Cisco MDS 9000, NetApp AFF A800, and NetApp FAS8200
- B. Cisco UCS 6324 Fabric Interconnect, Cisco B-Series servers, Cisco Nexus 9000 Series, Cisco MDS 9000, NetApp AFF A800, and NetApp FAS2700
- C. Cisco UCS 6332-16 Fabric Interconnect, Cisco B-Series servers, Cisco Nexus 9000 Series, Cisco MDS 9000, NetApp AFF A800, and NetApp FAS2700
- D. Cisco UCS 6296 Fabric Interconnect, Cisco B-Series servers, Cisco Nexus 9000 Series, Cisco MDS 9000, NetApp AFF A800, and NetApp FAS8200
Answer: D
NEW QUESTION 32
Which of the following must you successfully specify when configuring the NTLM authentication?
- A. RADIUS server
- B. Windows domain controller to use
- C. None of the above
- D. UNIX computer to use
Answer: B
NEW QUESTION 33
Cisco UCS Manager may be used to manage which four tasks within a Cisco UCS domain? (Choose four)
- A. Cisco UCS resource management including WWN addresses, MAC addresses, UUIDs, and bandwidth
- B. Deploy patches for software, such as an OS or an application
- C. Cisco UCS hardware including the chassis, servers, fabric interconnects, and i/o modules
- D. Install software applications, such as databases, application server software, or web servers
- E. Network administration such as creating VLANs, uplink ports, port channels and LAN PIN groups
- F. Deployment of a Windows or Linux Operating system
- G. SAN configuration tasks such as creating VSANs, QoS classes and definitions, and port channels.
- H. Management of non-Cisco x86 systems
Answer: A,C,E,G
NEW QUESTION 34
You are working with a customer on a new FlexPod solution. The customer advises you that they want a single point of contact for support issues.
In this scenario, which two support solutions should you offer the customer? (Choose two.)
- A. Cisco SmartNet Total Care
- B. NetApp Solution Support for FlexPod
- C. Cisco Solution Support
- D. NetApp SupportEdge Expert
Answer: A,B
NEW QUESTION 35
A customer wants to use a Cisco Nexus 93180YC-FX switch to support the FC protocol for booting from SAN without having to deploy additional Cisco 900 Series MDS switches in their FlexPod Datacenter configuration.
In this scenario, what is required for this solution?
- A. The customer must enable the FC license on the 93180YC-FX switch
- B. The customer must directly connect the NetApp AFF system to the Cisco UCS Fabric Interconnects
- C. The customer must add an expansion FC module to the 93180YC-FX switch
- D. The customer must deploy the 93180YC-FX switch as part of a Cisco ACI fabric
Answer: B
NEW QUESTION 36
Which UCS Manager feature will allow you to have a consistent server configuration within the system?
- A. address pools
- B. role-based access control
- C. same blade hardware configuration
- D. service profile templates
Answer: D
NEW QUESTION 37
Which of the following commands are used for running automated diagnostic analysis routines?
- A. diag list
- B. diag dump
- C. netstat -d
- D. ifstat -a
Answer: B
NEW QUESTION 38
Your customer has a FlexPod solution with a 2-node switchless ONTAP system, Cisco Nexus 93108 switches, and Cisco UCS B-Series servers. The customer wants to expand to a 4-node ONTAP storage cluster.
Which configuration is valid for expansion?
- A. Use the existing Nexus 93108 switches for the cluster interconnect.
- B. Add two Nexus 3232C switches for the cluster interconnect.
- C. Add two Nexus 93108 switches for the cluster interconnect.
- D. Add one Nexus 3232C switch for the cluster interconnect.
Answer: B
NEW QUESTION 39
Which protocol is currently supported on the Nexus 1000V to support network isolation among virtual machines beyond traditional VLANs for cloud-scale networking?
- A. Virtual Extensible Local Area Network (VXLAN)
- B. Overlay Transport Virtualization (OTV)
- C. Stateless Transport Tunneling (STT)
- D. vPath
Answer: A
NEW QUESTION 40
An ACI customer would like to enable devices from one Endpoint Group to talk to another Endpoint Group.
Which ACI construct is required to enable this capability?
- A. Endpoint
- B. Bridge Domain
- C. Application Profile
- D. Contract
Answer: D
NEW QUESTION 41
State whether the following statement is true or false. Disk ID is represented in x.y format, where x refers to the host adaptor and y refers to the disk ID number.
- A. True
- B. False
Answer: A
NEW QUESTION 42
You are asked to build a FlexPod solution using Application Centric Infrastructure (ACI).
What are two ways to address the network requirements for high availability in this scenario? (Choose two.)
- A. Deploy a single connected Cisco Application Policy Infrastructure Controller (APIC).
- B. Configure virtual Port Channels (vPCs).
- C. Use physical redundancy across the entire stack.
- D. Deploy the infrastructure in two data centers.
Answer: A,B
NEW QUESTION 43
A FlexPod solution is being designed using Nexus 9000 series switches.
What are three Layer 2 high-availability features that are available in this scenario? (Choose three.)
- A. First Hop Redundancy Protocols
- B. IEEE 802.3ad link aggregation
- C. Nonstop forwarding (NSF)
- D. Spanning Tree Protocol (STP)
- E. Unidirectional Link Detection (UDLD) protocol
Answer: B,D,E
NEW QUESTION 44
A customer has a FlexPod configuration that supports FC and uses Cisco MDS switches. The customer wants to add a 48-Port 32 Gbps Advanced Fibre Channel Switching blade to support both 32 Gbps FC and 32 Gbps NVMe-oF.
In this scenario, which Cisco switch is appropriate?
- A. MDS 9250i
- B. MDS 9148S
- C. MDS 9396S
- D. MDS 9706
Answer: B
NEW QUESTION 45
Network Appliance field alerts _______ and _________.
- A. are available at "www.netapp.com"
- B. may be received via email
- C. replace autosupport
- D. are available at "now.netapp.com"
Answer: B,D
NEW QUESTION 46
......
Pass Your NS0-175 Exam Easily with Accurate PDF Questions: https://www.getvalidtest.com/NS0-175-exam.html